Why a 24V Electric Linear Actuator Cannot Meet This 2,000 N, 60 mm/s, 400 mm Pulse-Controlled Project

Decision Item Standard 24 V Push Rod Required Motion Axis
Power at rod Often force-rated but speed-limited 120 W before drivetrain losses
Control Extend / retract, optional Hall feedback PLC pulse + direction position mode
Duty Commonly intermittent Repeated 400 mm production moves
Positioning Coasting, backlash, manual compensation Closed-loop servo control and alarms

Primary keyword: 24v electric linear actuator

Secondary keywords: electric cylinder solution; small linear motor actuator; servo motor electric linear actuator

1. The Requirement Is Not a Simple Extend-and-Retract Job

At first glance, the customer’s request sounds like a common linear-motion application: push a 2,000 N load over a 400 mm stroke using a 24 V DC supply. A catalog search may quickly show several 24v electric linear actuator models that claim a 2,000 N force rating and a 400 mm stroke option. That can create the impression that a standard electric push rod is sufficient.

The actual requirement is much more demanding. The actuator must move 2,000 N at 60 mm/s, repeat that motion through the full stroke, and accept pulse-signal control from a PLC. These conditions change the product category. A conventional 24v electric linear actuator is normally designed for intermittent, two-position movement. The project requires a controlled positioning axis.

In this article, “electric push rod” means a compact actuator built around a brushed DC motor, a high-ratio gearbox, an Acme or trapezoidal screw, and internal limit switches. Some models may include Hall pulses for feedback, but they do not normally include a servo drive, position mode, controlled acceleration, following-error monitoring, or a rated continuous-duty motion profile. That distinction is the key reason the standard product should not be selected.

A specially built actuator could meet the requirement, but it would need a larger motor, closed-loop controller, ball screw, brake, and continuous-duty rating. Once those features are added, it is no longer a basic push rod; it becomes a servo motor electric linear actuator or a complete electric cylinder solution.

blank

Figure: Comparison of an open-loop 24V electric push rod and a pulse-controlled servo electric cylinder

2. The Force Rating Alone Hides the Power Problem

The most common selection mistake is to compare only force and stroke. Force describes how hard the actuator can push, but it does not say how fast it can push that load. The customer requires both at the same time.

The required mechanical output is:

P mechanical = F × v = 2,000 N × 0.06 m/s = 120 W

That 120 W is the useful power at the moving rod, before motor, gearbox, screw, seal, and guide losses. A basic push rod often uses an Acme or trapezoidal screw and several reduction stages. If the combined drivetrain efficiency is 50%, the required electrical input is approximately:

P input = 120 / 0.50 = 240 W

At 24 V, that corresponds to about 10 A before acceleration, starting current, control losses, or reserve. If the real efficiency is closer to 40%, the demand rises to 300 W and 12.5 A. A compact actuator that appears acceptable from a force table may therefore be undersized by a factor of two or three at the required speed.

This is where a small linear motor actuator package becomes misleading. The housing may be compact, but the physics do not change: if the motor cannot continuously deliver enough power through the gearbox and screw, the actuator cannot maintain 2,000 N at 60 mm/s.

3. High Force and High Speed Pull the Gear Ratio in Opposite Directions

A conventional push rod obtains high force through a large reduction ratio: the motor spins quickly, the screw turns slowly, and the rod moves only a few millimeters per second. Increasing the ratio increases force but reduces speed; reducing it increases speed but sacrifices force.

For a fixed mechanical power level, the relationship is direct:

v = P / F

At 2,000 N:

  • A 20 W mechanical drivetrain supports only about 10 mm/s.
  • A 40 W mechanical drivetrain supports only about 20 mm/s.
  • The project requires 120 W mechanical output for 60 mm/s.

This is why a “2,000 N” label by itself is not enough. The force–speed curve must pass through the required point, not merely touch the required force at a much lower speed. The manufacturer’s continuous rating, not a short-term peak rating, must be used.

blank

Figure: Force-speed gap between a typical low-power push rod and the project requirement

A servo-based electric cylinder solution addresses this problem differently. It combines a 200 W servo motor, a properly selected planetary gearbox, and an efficient ball screw. The selection is made from torque, speed, efficiency, duty cycle, and thermal margin together, rather than from force alone.

4. The Duty Cycle Becomes a Thermal Risk

The 400 mm stroke also creates a duty-cycle problem. At 60 mm/s, one direction takes:

t = 400 / 60 = 6.67 s

A forward and return move takes approximately 13.33 seconds before any process dwell. If the machine repeats this motion every 30 seconds, the actuator is active for about 44% of the cycle. A push rod rated for a 20% duty cycle would exceed its rating in that example.

Heat is generated in the brushed motor, brushes, gearbox, screw nut, and thrust bearings. A simple H-bridge or relay control does not manage torque and thermal loading like a servo drive. As temperature rises, speed drops, current increases, brush wear accelerates, and thermal protection may stop the axis.

The requirement implies a production axis, so the actuator must be evaluated by continuous force, speed, ambient temperature, cycle time, and expected life. A compact 24v electric linear actuator intended for occasional adjustment is not a substitute for a rated industrial positioning cylinder.

Elektrozylinder

Hochleistungs-Linearantriebe und elektrische Servomotorzylinder in der Luft- und Raumfahrt sowie in militärischen Anwendungen

5. PLC Pulse Control Is Not the Same as Hall Feedback

The phrase “pulse signal control” is often misunderstood. In a PLC motion application, pulse control normally means the PLC sends a high-speed pulse train and direction signal to a servo or stepper drive. Each command pulse represents a defined increment of motion. Acceleration, deceleration, target distance, and following error are managed by the drive.

Many standard push rods advertise “pulse feedback,” but that is the opposite direction of information flow. A Hall sensor may output pulses while the motor turns, allowing an external controller to estimate position. The push rod still does not accept a pulse-train position command. The external controller must switch the DC motor on and off, count feedback pulses, predict coasting distance, compensate for load changes, and reverse the motor when overshoot occurs.

That method is fragile on a 2,000 N axis. Motor speed changes with voltage, temperature, load, and brush condition; backlash separates motor position from rod position; and inertia prevents an immediate stop. Accurate intermediate positioning becomes difficult.

A servo motor electric linear actuator uses the pulse train as a command input. The servo drive closes the current, velocity, and position loops. It can execute a trapezoidal profile, monitor following error, and report an alarm if the axis cannot keep up. That is the control architecture the customer’s PLC requirement actually calls for.

blank

Figure: Qualitative positioning comparison between a conventional push rod and a closed-loop servo actuator

6. Repeatability, Backlash, and Coasting Limit Positioning Quality

Even if an external controller succeeds in counting Hall pulses, the pulses are normally measured at the motor or an early gear stage. They do not directly measure the rod. Backlash in spur gears, worm gears, couplings, and the screw nut creates lost motion between the motor and the load.

During reversal, the motor turns through backlash before the rod moves. During stopping, inertia can carry the rod past the target. A controller can compensate, but the correction changes with load, wear, voltage, and temperature.

For simple end-to-end motion these errors may not matter; for pulse-controlled positioning they become functional defects. A standard push rod usually cannot report following error, command position, torque status, or a drive fault like a servo system can.

7. Holding Force and Safety Are Not Guaranteed

Some Acme-screw push rods can hold a load when power is removed because the screw has high friction or self-locking behavior. That feature should never be assumed without manufacturer confirmation. Vibration, wear, lubrication, screw lead, and back-driving torque can change the result. Dynamic braking of a brushed motor is also not the same as a rated holding brake.

For this project, the actuator may need to stop at an intermediate position and hold the load while the machine performs another operation. A servo drive provides controlled holding torque, and the motor can be specified with a fail-safe brake for vertical or safety-critical mounting. The PLC can monitor drive ready, alarm, home, and limit signals. A basic push rod normally provides much less diagnostic information.

Safety also requires predictable stopping. Removing motor power may allow coasting, while shorting a brushed motor creates an uncontrolled dynamic-braking stop. Neither replaces a tested servo stop and safety design.

8. The 400 mm Stroke Adds Mechanical and Life Constraints

A 400 mm stroke is available in many push-rod catalogs, but stroke availability does not prove suitability. At 2,000 N, the screw and thrust bearing must be checked for buckling, bearing life, nut wear, lubrication, mounting alignment, and side load. At higher speed, wear and heat increase. At higher force, gearbox tooth loading and thrust-bearing stress increase.

A rod-style actuator should not absorb side load or moment. If the customer’s tooling is not guided, the rod bushing and screw will wear quickly. A dedicated electric cylinder solution provides a more suitable mechanical platform, but external linear guides should still be added when the application creates side load.

The design must also include homing, overtravel protection, emergency stopping, cable routing, contamination protection, and maintenance access. Internal end switches alone do not provide these structured motion-control functions.

9. What Would Be Required to Make a Push Rod Work?

To make a conventional push rod approach this requirement, the design would need several upgrades:

  • A larger continuous-duty motor with sufficient thermal margin
  • A more efficient screw and gearbox
  • A motor controller with current limiting and controlled acceleration
  • Position feedback and a closed-loop positioning algorithm
  • A holding brake or verified power-off holding method
  • Published force–speed, duty-cycle, and life data at the required operating point
  • PLC-compatible pulse input or a dedicated motion controller
  • Proper alarm, limit, homing, and safety circuits

At that point, the machine builder has effectively redesigned a servo motor electric linear actuator. The cost, development time, panel space, and validation risk may exceed the price of selecting a purpose-built servo electric cylinder in the first place.

10. Final Engineering Conclusion

A standard 24v electric linear actuator is the wrong choice for this project because the limiting requirement is not force alone. The axis must deliver 2,000 N at 60 mm/s, which requires 120 W of mechanical power before drivetrain losses. It must also repeat a 400 mm move under PLC pulse control, hold position predictably, and survive a production duty cycle.

A typical push rod is optimized for compact, intermittent extend-and-retract motion. Its high reduction ratio creates force at the expense of speed, its brushed motor and screw generate heat, its feedback pulses do not provide pulse-position control, and its backlash and coasting limit repeatability. Adding the missing components would turn it into a different product.

For this application, the defensible choice is a 52-size electric cylinder solution using a 24 V 200 W servo motor, servo drive, suitable reduction, precision ball screw, and PLC pulse control. It matches the load-speed requirement, provides closed-loop positioning, and gives the machine builder the alarms and diagnostics needed for reliable production. A conventional push rod may look cheaper on a parts list, but it does not meet the engineering requirement as a complete motion axis.

 

Our facebook page; Our Youtube chanel; Our Linkedin page;